eX Series PDF


 

The eX 801S Single CPC Main Frame houses all the module cards and distributes the incoming power supply to the frame's multi-voltage power supply rail. The main frame features ten card slots for various module cards, Central Processing Card (CPC), and the Power Supply Inlet Card. The eX 801S utilizes a CPC to control and monitor all operation. The front panel of the main frame is integrated with indicators to state the status of the unit such as Power, CPU off, Fault and Status. The main frame also transmits audio and data information to the extension frame for additional module cards if required.

eX 801S / 802S

Power Requirement 24 Vdc (Regulated), 1.5 A

No. of Central Processing Card

1 no. eX 821S

No. of Power Supply
Inlet Card

1 no. eX 881S

No. of Card Slot per Frame

10 (eX 801S)
9 (eX 802S)

Indication Power, CPU OFF, Fault, Status (eX 801S)

Power, CPU OFF, Fault, Status 1, Status 2 (ex 802S)

  Material & Finish

Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

  Dimensions (W x H x D)

483 x 133 x 200mm
  Weight

2.9 kg (eX 801S)
3.1 kg (eX 802S)


The Extension Frame is used when additional module cards are needed to cater for a more extensive public address system. Similar to the main frame, the extension frame accepts power supply and converts it to a lower voltage for module cards usage. The eX 803S features ten card slots, Extension Card and Power Supply Inlet Card. Status indicator for Power is available on the front panel of the frame.

  eX 803S

  Power Requirement 24 Vdc (Regulated), 1.5 A

  No. of Power Supply
Inlet Car
1 no. eX 881S


  No. of Extension Card 1 no. eX 824S

  No. of Card Slot per Frame 10


  Material & Finish

Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

  Dimensions (W x H x D) 483 x 133 x 200 mm

  Weight

2.7 kg


The eX 811S Control Manager is the proprietary software which is exclusively integrated with the eX 800S Series to enable the user to configure and customize the eMatrix System to suite its application. It allows user to configure input channel, output zones, time scheduler, failure output patterns, system diagnosis settings and many other functions. The Control Manager supports up to 3500 event logs, which records the system’s activities and faults. software which is exclusively integrated with the eX 800S Series to enable the user to configure and customize the eMatrix System to suite its application. It allows user to configure input channel, output zones, time scheduler, failure output patterns, system diagnosis settings and many other functions. The Control Manager supports up to 3500 event logs, which records the system’s activities and faults. Moreover, the software enables the user to perform tests to check the status of audio path, hardware cards and so on. It also provides a constant monitoring system so that the eMatrix System is in optimum working condition. For security reason, the software provides 3 types of user access level password protection for authorised user, operator and visitor.


The Central Processing Card has a built-in Real Time Clock and a CPU fault detection circuit. The Central Processing Card main function is to coordinate the activities of the module cards as well as to process the configuration from Control Manager to the respective module cards. The card is integrated with various connectors to allow it to communicate with other system such as the iX 156E, ix 157E and iX 159E. The eX 821S card is also able to coordinate a simultaneous voice evacuation process using its onboard Evacuation Management System.

eX 821S

Connector 1 No. RJ 45 Connector
1 No. USB Connector
1 No. DB9 Female Connector

Power Requirement 24 Vdc (From Backplane), 650 mA

Material & Finish Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

Dimensions (W x H x D) 45 x 128 x 173mm

Weight 160 g



The eX 822S works as a hot-standby Central Processing Card (CPC) for the eX 821S. The module slots into a dedicated slot in the eX 802S Dual CPC Main Frame and monitors the operation of the primary CPC. In the event of failure to the primary CPC, the secondary CPC will automatically take over the entire operation. The switchover is instantaneous while an audible warning is emitted in the event of failure for rectification work. Every event is logged for reporting and available for print-out from the GUI.


eX 822S

Connector 1 No. RJ 45 Connector
1 No. USB Connector
1 No. DB9 Female Connector

Power Requirement 24 Vdc (From Backplane), 650 mA

Material & Finish Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

Dimensions (W x H x D) 35.5 x 128 x 173mm

Weight 130 g



The eX 821SE is the Central Processing Card that converts the eX 800S Matrix Sound Management System into a full fledged Early Evacuation System (EES) for internal hazards such as a fire or gas leak (Phased Evacuation) while the eX 821SX performs both internal hazard evacuation and external hazard evacuation such as a bomb threat or threat from adjacent building (Optimal Evacuation). The EES automates the evacuation process of the entire building upon receiving the trigger signal from the fire alarm system or either by manual triggering. The system is able to simultaneously broadcast up to 32 different messages to different areas to alert people during an emergency situation.

eX 821SE / eX 821SX

Connector 1 No. RJ 45 Connector
1 No. USB Connector
1 No. DB9 Female Connector

Power Requirement 24 Vdc (From Backplane), 650 mA

Material & Finish Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

Dimensions (W x H x D) 45 x 128 x 173mm

Weight 160 g



The eX 822SE works as a hot-standby Central Processing Card (CPC) for the eX 821SE while the eX 822SX is for the eX 821SX. The module slots into a dedicated slot in the eX 802S Dual CPC Main Frame and monitors the operation of the primary CPC. In the event of failure to the primary CPC, the secondary CPC will automatically take over the entire operation. The switchover is instantaneous while an audible warning is emitted in the event of failure for rectification work. Every event is logged for reporting and available for print-out from the GUI.

eX 822SE / eX 822SX

Connector 1 No. RJ 45 Connector
1 No. USB Connector
1 No. DB9 Female Connector

Power Requirement 24 Vdc (From Backplane), 650 mA

Material & Finish Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

Dimensions (W x H x D) 35.5 x 128 x 173mm

Weight 130 g



This card serves as a data and audio signal transmission link to the extension frame via 4 RJ45 connectors. It enables the main frame to communicate with the extension frame.


eX 823S

Connector 4 Nos. RJ 45 Connector

Power Requirement 24 Vdc (From Backplane), 100 mA

Material & Finish Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

Dimensions (W x H x D) 35.5 x 128 x 173mm

  Weight

310 g


This card receives data and audio signal from the main frame. Supports data and audio signal transmission to other extension frame if required via 8 RJ 45 connectors.

eX 824S

Connector

8 Nos. RJ 45 Connector

Power Requirement

24 Vdc (From Backplane), 80 mA
Material & Finish Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

Dimensions (W x H x D) 45 x 128 x 173mm

  Weight

190 g


The eX 831S Auxiliary Input Card serves as the pre-amplifier for sources like background music, digital messages and microphones. Each card features two Auxiliary Inputs with Control Input. The audio inputs feature jumper settings for either microphone (-70dB to -45dB) or line in (-20dB to 8dB). The Auxiliary inputs are stereo inputs for background music player and individual gain can be adjusted via recessed potentiometer. The card can also provide phantom power if connected to a condenser microphone. The eX 831S card utilises RJ45 connectors for both audio input and control input. This card is to be installed in the eX 801S or eX 802S Main Frame only.

eX 831S

No. of Channel

2

Input Sensitivity

MIC: -70 to -45 dB (adjustable) with built in Audio Limiter, 600 Ω, unbalanced
LINE: -20 to +8 dB (adjustable), 10 kΩ, balanced MIC or LINE selectable by the built-in jumper

Low Frequency Filter (100 Hz)

-15 dB to + 15 dB Boost & Cut (adjustable)
High Frequency Filter (10 kHz)

-15 dB to + 15 dB Boost & Cut (adjustable)
  Distortion

<0.5%
  Frequency Response

20Hz - 20kHz
  Phantom Power

7.5V

  Control Input

Dry Contact Activation
  Control

2 Nos. Volume Control
  Connector

2 Nos. RJ 45 Connector
  Power Requirement 24 Vdc (From Backplane), 30 mA

  Material & Finish

Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

  Dimensions (W x H x D)

35.5 x 128 x 173mm
  Weight

157 g


The eX 832S Auxiliary Input and Digital Source Card is a 2-in-1 card which features an auxiliary input (switchable between MIC and LINE level) as well as a digital source module which stores and plays audio files in MP3 format. The digital source module utilizes Multimedia Card (MMC) as a storage medium which is able to store up to 128 background music (BGM) or messages in a single card. Similar to the eX 831S, the eX 832S features jumper selection settings, stereo inputs, phantom power and individual gain control. The eX 832S provides an RJ45 connector for Audio and Control Input as Auxiliary Input and a USB port for file transfer to the MMC. This card is to be installed in the eX 801S or eX 802S Main Frame only.

eX 832S

No. of Channel

1 Channel - AUX Input
1 Channel - Digital Source

Input Sensitivity
for AUX Input

MIC: -70 to -45 dB (adjustable) with built in Audio Limiter, 600Ω, unbalanced
LINE: -20 to +8 dB (adjustable), 10 kΩ, balanced MIC or LINE selectable by the built-in jumper

Low Frequency Filter
( 100 Hz ) - for AUX Input

-15 dB to +15 dB Boost & Cut (adjustable)

High Frequency Filter
( 100 Hz ) - for AUX Input

-15 dB to +15 dB Boost & Cut (adjustable)

  Distortion

< 0.5 % - AUX Input
< 0.5 % - Digital Source

  Frequency Response

20 Hz - 20 kHz - AUX Input
20 Hz - 20 kHz ( 44.1 kHz sampling ) - Digital Source

  Control Input

Dry Contact Activation

  Control

1 No. Volume Control
  Connector 1 No. RJ 45 Connector - AUX Input
1 No. USB Connector - Digital Source

  External Storage Multimedia Card (MMC)

  Playback Mode Single Source Playback

  No. of Playback
Program

128 Programs
  Power Requirement 24 Vdc (From Backplane), 30 mA

  Material & Finish Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

  Dimensions (W x H x D) 35.5 x 128 x 173mm

  Weight 200 g



The eX 833S Dual Channel Digital Source Card provides 2 channels of digital source for both messages and audio files. It is able to store and playback up to 128 BGM or messages per card and uses Multimedia Card (MMC) as a storage medium. Moreover, the card is integrated with two USB ports for file transfer to the MMC via a personal computer. This card is to be installed in eX 801S or eX 802S Main Frame only.

eX 833S

No. of Channel

2

Distortion

<0.5%
Frequency Response

20Hz - 20kHz

Playback Mode

Dual source playback

  No. of Playback
Program

128 Program - Each Channel

  Connector

2 Nos. USB Connector

  Power Requirement

24 Vdc (From Backplane), 100 mA

  Material & Finish

Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

  Dimensions (W x H x D) 35.5 x 128 x 173mm

  Weight 220 g



The eX 834S Microphone Input Card provides two inputs for Remote Microphones and Emergency Microphones. Each input channel is able to communicate with eight Remote Microphones or a combination of four Emergency Microphones and 4 Remote Microphones. The eX 834S utilizes RJ45 connectors for Audio and Data Input. This card is to be installed in eX 801S or eX 802S Main Frame only.

eX 834S

No. of Channel

2

Connectable Microphone

eX 865S, eX 866S, eX 867S, eX 868S, eX 861S, eX 862S, eX 863S, eX 864S

Connector 2 Nos. RJ 45 Connector

Power Requirement

24 Vdc (From Backplane), 100 mA
  Material & Finish
Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

  Dimensions (W x H x D)

35.5 x 128 x 173mm

  Weight 158 g


The eX 837S provides two 0 dB electronically balanced audio outputs with individual gain control via the Control Manager software. A dry contact output is available to provide external control which can be used for overriding the audio attenuator when the channel is activated. The module either connects directly to the power amplifier inputs or through the LA 08 Integrated Supervisory Unit for line supervisory & amplifier changeover purposes.

eX 837S

No. of Channel

2

Output Level & Impedance

0 dBV, 600Ω Balanced

Control Output NO or NC Dry Contact (Max 24 Vdc, 1 A)

Connector

2 Nos. RJ 45 Connector;
1 No. 1 x 4-Pin Panel Feed Through Connector

  Power Requirement 24 Vdc (From Backplane), 150 mA
  Material & Finish
Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

  Dimensions (W x H x D)

35.5 x 128 x 173mm

  Weight 205 g


The eX 839S is similar with the eX 837S with additional built-in line supervisory using impedance measurement technique for both channels and amplifier switchover function in the event of amplifier failure. When a loudspeaker line short circuit is detected, the module automatically isolates the power amplifier from the faulty line to prevent it from damage. The module enables the system to comply to the IEC/EN 60849 requirement that calls for two separate loudspeaker circuits in one loudspeaker zone. There are two selectable modes of operation : Continuous Monitoring (as required by IEC/EN 60849) or Scheduled Monitoring. Continuous monitoring requires an additional end-of-line detector module and a pair of return cable back to the unit.

eX 839S

No. of Channel

2

Output Level & Impedance

0 dBV, 600Ω Balanced

Control Output NO or NC Dry Contact (Max 24 Vdc, 1 A)

Connector

2 Nos. RJ 45 Connector;
1 No. 2 x 14-Pin Panel Feed Through Connector

  Power Requirement 24 Vdc (From Backplane), 150 mA
  Material & Finish
Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

  Dimensions (W x H x D)

35.5 x 128 x 173mm

  Weight 250 g


The eX 841S Control Input Card provides up to 16 control sensor inputs where it is able to receive dry contact signals provided by any external system. All the inputs are opto-isolated. These sensor inputs data will be transmitted to the Central Processing Unit for further processing.

eX 841S

No. of Channel

16

Sensing Method

Dry Contact or Current Loop (jumper selectable)

Dry Contact Method
NO or NC (jumper selectable)

Current Loop Method

Released Voltage 24 Vdc, 5 mA

  Connector

4 Nos. RJ 45 connector
  Power Requirement 24 Vdc (From Backplane), 100 mA

  Material & Finish

Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

  Dimensions (W x H x D)

35.5 x 128 x 173mm

  Weight

158 g



The eX 842S Control Output Card provides up to 16 make/break relay contact outputs where it transmits output signal to any external system. Each card channel is able to withstand voltage of 24 Vdc / 120 Vac and control current of 250mA.

eX 842S

No. of Channel

16

Triggering Method

NO or NC Dry Contact (jumper selectable)

Withstand Voltage 24Vdc, 250mA

Connector

4 nos. RJ 45 Connector
  Power Requirement 24 Vdc (From Backplane), 320 mA

  Material & Finish

Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

  Dimensions (W x H x D)

35.5 x 128 x 173mm

  Weight

230 g



The Emergency Microphone produces 0 dB Audio Balanced Output and communicates with eX 834S Microphone Input Card via RS 485 Communication line. Each communication line is able to connect 4 Emergency and 4 Remote Microphones or 8 Remote Microphones. It has a maximum distance of 1.2 km for a single Emergency Microphone. The Emergency Microphone features a built-in siren, audio gain control and auto mic OFF when it is left unattended. The Emergency Microphones are equipped with programmable function keys. These function keys can be programmed to perform zone selection, relay activation or any other matrix activities. There are four models for Emergency Microphones, namely eX 861S (10 functions), eX 862S (20 functions), eX 863S (40 functions) and eX 864S (120 functions). The microphones can either be a desktop unit or wall mounted using optional mounting bracket.

eX 861S

eX 862S
Output Level &
Impedance

0 dBV 600Ω Balanced

0 dBV 600Ω Balanced
Mircophone

Handheld Omni-Directional Microphone Handheld Omni-Directional Microphone
Distortion <1%

<1%
Frequency
Response

100Hz - 20kHz
100Hz - 20kHz
  Signal-to-Noise
Ratio

> 60dB
> 60dB
  Internal Monitor Speaker

0.5W 0.5W
  Volume Control

Microphone Level
Control,Monitor Speaker
Level Control, Siren
Level Control.

Microphone Level
Control,Monitor Speaker
Level Control, Siren
Level Control.
  Auto Mic OFF 15 sec. to 2 min.

15 sec. to 2 min.
  Number of Programmable Functions

10

20
  Number of Connectable
Units

4 4
  Communication Protocol

RS 485

RS 485
  Connector

RJ 45, plug-in screw connector

RJ 45, plug-in screw connector
  Communication Distance

1.2 km 1.2 km
  Power Requirement

24 Vdc (Regulated), 300 mA

24 Vdc (Regulated), 320 mA
  Material & Finish

ABS Resin & Aluminium, Epoxy Powder Coated Steele Blue (RAL 5011 )
ABS Resin & Aluminium, Epoxy Powder Coated Steele Blue (RAL 5011 )

  Dimensions
(W x H x D)

265 x 64.5 x 185mm 265 x 64.5 x 185mm
  Weight

1.3 kg 1.3 kg

eX 863S

eX 864S
Output Level &
Impedance

0 dBV 600Ω Balanced

0 dBV 600Ω Balanced
Mircophone

Handheld Omni-Directional Microphone

Handheld Omni-Directional Microphone

Distortion <1%

<1%
Frequency
Response

100Hz - 20kHz 100Hz - 20kHz
  Signal-to-Noise
Ratio

>60 dB >60 dB
  Internal Monitor Speaker

0.5 W 0.5 W
  Volume Control

Microphone Level
Control,Monitor Speaker
Level Control, Siren
Level Control

Microphone Level
Control,Monitor Speaker
Level Control, Siren
Level Control
  Auto Mic OFF 15 sec. to 2 min.

15 sec. to 2 min.
  Number of Programmable Functions

40

120
  Number of Connectable Units

4 4
  Communication Protocol

RS 485 RS 485
  Connector

RJ 45, plug-in screw connector

RJ 45, plug-in screw connector
  Communication Distance

1.2km 1.2km
  Power Requirement

24 Vdc (Regulated), 320 mA

24 Vdc (Regulated), 420 mA
  Material & Finish

ABS Resin & Aluminium, Epoxy Powder Coated Steele Blue (RAL 5011 )
ABS Resin & Aluminium, Epoxy Powder Coated Steele Blue (RAL 5011 )
  Dimensions
(W x H x D)

265 x 64.5 x 185mm 475 x 64.5 x 185mm
  Weight

1.3 kg 2.0 kg


The Remote Microphone produces 0 dB Balanced Audio Output and communicates with the eX 834S Microphone Input Card via RS 485 communication. Each communication line can support up to 4 Emergency and 4 Remote Microphones or 8 Remote Microphones. Maximum cabling distance is 1.2 km (for a single Remote Microphone). The Remote Microphone features a built-in chime, audio gain control and Auto Mic Off if left unattended for a preset period of time. The Remote Microphone are equipped with programmable function keys. These function keys can be programmed to perform zone selection, relay activation or any other matrix activities. There are four models for Remote Microphones, namely eX 865S (10 functions), eX 866S (20 functions), eX 867S (40 functions) and eX 868S (120 functions). The microphones can be desktop unit.


eX 865S

eX 866S
Output level &
Impedance

0 dBV 600Ω Balanced 0 dBV 600Ω Balanced
Gooseneck Mircophone Undirectional electret
condenser microphone


Undirectional electret
condenser microphone
Distortion

<1%
<1%
  Frequency
Response

100 Hz - 20 kHz
100 Hz - 20 kHz
  Signal-to-Noise
Ratio

> 60dB > 60dB
  Internal Monitor Speaker

0.5W

0.5W
  Volume Control Microphone Level
Control, Monitor
Speaker Level Control,
Chime Level Control.

Microphone Level
Control, Monitor
Speaker Level Control,
Chime Level Control.

  Auto Mic OFF 15 sec. to 2 min.

15 sec. to 2 min.
  Number of Programmable Functions

10 20
  Number of Connectable Units

8 (include Emergency Mic)
8 (include Emergency Mic)
  Communication Protocol

RS 485

RS 485
  Connector

RJ 45, Panel Feed Through
Connector
RJ 45, Panel Feed Through
Connector

  Communication Distance

1.2 km 1.2 km
  Power Requirement 24 Vdc (Regulated), 230 mA

24 Vdc (Regulated), 250 mA
  Material & Finish

ABS Resin & Aluminium Epoxy Powder Coated Steele Blue
(RAL 5011)
ABS Resin & Aluminium Epoxy Powder Coated Steele Blue
(RAL 5011)

  Dimensions
(W x H x D)

210 x 64.5 x 185 mm 210 x 64.5 x 185 mm
  Weight

1.2 kg 1.2 kg

eX 867S

eX 868S
Output level &
Impedance

0 dBV 600Ω Balanced 0 dBV 600Ω Balanced
Gooseneck
Mircophone
Undirectional electret
condenser microphone
Undirectional electret
condenser microphone

Distortion

<1%
<1%
  Frequency
Response

100 Hz - 20 kHz
100 Hz - 20 kHz
  Signal-to-Noise
Ratio

> 60dB > 60dB
  Internal Monitor Speaker

0.5 W

0.5 W
  Volume Control Microphone Level
Control, Monitor
Speaker Level Control,
Chime Level Control.

Microphone Level
Control, Monitor
Speaker Level Control,
Chime Level Control.

  Auto Mic OFF 15 sec. to 2 min.

15 sec. to 2 min.
  Number of Programmable Functions

40 120
  Number of Connectable Units

8 (include Emergency Mic)

8 (include Emergency Mic)
  Communication Protocol

RS 485

RS 485
  Connector

RJ 45, Panel Feed Through
Connector

RJ 45, Panel Feed Through
Connector
  Communication Distance

1.2 km 1.2 km
Power Requirement 24 Vdc (Regulated), 250 mA

24 Vdc (Regulated), 350 mA
  Material & Finish

ABS Resin & Aluminium Epoxy Powder Coated Steele Blue (RAL 5011 ) ABS Resin & Aluminium Epoxy Powder Coated Steele Blue (RAL 5011)

  Dimensions
(W x H x D)

210 x 64.5 x 185 mm 430 x 64.5 x 185
  Weight

1.2 kg 1.8 kg


The eX 881S Power Supply Inlet Card accepts regulated 24 Vdc power supply through its 3 pin terminal block, which includes an earth termination. The card also provides power failure and CPU off dry contact outputs to external system.

eX 881S

Power Handling

24 Vdc (Regulated), 3 A

Connector

1 No. 3-Pin Terminal Block;
1 No. 4-Pin Panel Feed Through Connector

Material & Finish
Mild Steel; Exopy Coated Steele Blue (RAL 5011)

  Dimensions (W x H x D)

19.5 x 128 x 173 mm

  Weight 100 g

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The use of the ES 100 Emergency Power Supply is for systems that require a secondary power supply to be available following primary power failure. The unit connects to a battery bank, with automatic charging and monitoring with fault reporting to the main system. In the event of primary power failure, the battery supply is switched over to the equipments connected to it. The unit prevents over discharging to prolong the battery life. Recharging resumes once the primary power is returned.

 


Site Map | Privacy Policy | Terms of Use
© 2005 - 2008 AEX System. All Rights Reserved.