The
iX 101 & iX 102, Single and Dual CPC Main Frame are rack-mountable
frames and used to house the Digital Matrix System modular cards.
Both can accommodate up to 12 matrix cards. All the Digital Matrix
audio and remote microphone input cards shall be placed within this
frame. This main frame comes complete with a front access LCD panel
with selection scroll keys; 1 unit of iX 182 Power Supply Unit; 1
unit of iX 194 Analogue Handheld Microphone; 1 unit of iX 121 Central
Processing Card I for iX 101 (2 units of iX 121 Central Processing
Card I for iX 102); 1 unit of iX 132 Audio Input Card; 1 unit of iX
133 Remote Microphone Input Card and 2 units of iX 136 Audio Output
Cards.
|
|
iX
101 / 102
|
|
Input
Capacity |
12
Cards
|
|
Available
Card Slots |
7
Slots (iX 101)
6 Slots (iX 102)
|
|
Microphone |
iX
194 Analogue Handheld Microphone
|
|
Indicator
(Facial) |
240
x 128 Dot Matrix LCD
|
|
Control
(Facial) |
4
nos. Scroll keys
2 nos. Function keys
1 no. LCD Contrast control
1 no. Gain adjust for iX 194 Analogue
Handheld Microphone
|
| |
Number
of Audio Input Channel
|
4
nos.
|
| |
Audio
Input Sensitivity & Impedance
|
0
dBV, 10 kΩ, Balanced
|
| |
Number
of Audio Control Input
|
4
nos. Dry-contact Activation
|
| |
Number
of Remote Microphone Input Channel
|
4
nos.
|
| |
Remote
Microphone Input Sensitivity & Impedance
|
+
6 dBV, 10 kΩ, Balanced
|
| |
Number
of Data Communication Channel
|
4
nos.
|
| |
Data
Communication Protocol
|
RS-485
|
| |
Number
of Audio Output Channel
|
8
nos.
|
| |
Audio
Output Level & Impedance
|
0
dBV, 600 Ω, Balanced
|
| |
Number
of Audio Control Output
|
8
nos. Opto-coupler Activation
|
| |
Frequency
Response |
20
Hz to 20 kHz (-3 dB)
|
| |
Signal-to-Noise
Ratio |
>
80 dB (@ 0 dBV)
|
| |
THD
+ N |
<
0.03% (@ 1 kHz)
|
| |
Power
Requirement |
240
Vac, 50 Hz
DC Backup: 24 Vdc, 6.5 A
|
| |
Material
& Finish |
Mild
Steel; Epoxy Coated
Steele Blue (RAL 5011)
|
| |
Dimensions
(W x H x D) |
483
x 221 x 360 mm
|
| |
Weight |
12.2
kg (iX 101)
12.6 kg (iX 102)
|
The
iX 103, Extension Frame is a rack-mountable frame and is used to house
the Digital Matrix System modular cards. It can accomodate up to 12
matrix cards. This extension frame comes complete with 1 unit of iX
182 Power Supply Unit; 1 unit of iX 122 Central Processing Card II;
1 unit of iX 123 Extension Card; 1 unit of iX 191 Network Bus and
1 unit of iX 192 Audio Bus.
|
|
iX
103
|
|
Input
Capacity |
12
Cards
|
|
Available
Card Slots |
10
Slots
|
|
Power
Requirement |
240
Vac, 50 Hz
DC Backup: 24 Vdc, 6.5 A
|
|
Material
& Finish |
Mild
Steel; Epoxy Coated Steele Blue (RAL 5011)
|
|
Dimensions
(W x H x D)
|
483
x 221 x 360 mm
|
| |
Weight |
10
kg |
The
iX 121, Central Processing Card I is the main controller that manage
the entire matrix system operation. It is to be installed in the iX
101 or iX 102 Matrix Main Frame. It occupies Slot-1 of iX 101 Main
Frame or Slot-1 and Slot-2 of iX 102 Main Frame. This card will be
connected to PC via the RS-232 Serial Communication Port for system
configuration upload and system status download. This RS-232 port
is also used to connect to iX 155 Internet Connectivity Panel, via
a selector slide switch on the panel facial. Two units of iX 121 will
be installed into the iX 102, Dual CPC Matrix Main Frame.
|
|
iX
121
|
|
Connection |
2
nos. 9-pin D-sub (Female) Connector - CAN
1 no. 9-pin D-sub (Male) Connector - RS-232
|
|
Indicator |
1
no. Power LED
1 no. Faulty LED
1 no. Operation LED
|
|
Control |
1
slide switch
|
|
Backup
Power |
Internal
Battery, 3V Lithium
|
|
Material
& Finish
|
Mild
Steel; Epoxy Coated Steele Blue (RAL 5011) |
| |
Dimensions
(W x H x D)
|
26
x 220 x 286 mm |
| |
Weight
|
354
g |
The
iX 122, Central Processing Card II is installed in the iX 103, Matrix
Extension Frame. It occupies Slot-1 of the Extension Frame. The central
processing cards between frames are connected through Controller Area
Network (CAN) Protocol.
|
|
iX
122
|
|
Connection |
2
nos. 9-Pin D-sub (Female) Connector -CAN
|
|
Indicator |
1
no. Power LED
1 no. Faulty LED
1 no. Operation LED
|
|
Material
& Finish |
Mild
Steel; Epoxy
Coated Steele Blue (RAL 5011)
|
|
Dimensions
( W x H x D) |
26
x 220 x 286 mm
|
|
Weight |
321
g |
The
iX 123, Extension Card transfers the digital audio signals, control
and communication signals from one frame to another. It shall be placed
next to the iX 121 or iX 122.
|
|
iX
123
|
|
Connection |
1
nos. 50-Pin Centronic (Female) Connector
|
|
Material
& Finish |
Mild
Steel; Epoxy Coated Steele Blue (RAL 5011)
|
|
Dimensions
(W x H x D) |
26
x 220 x 286 mm
|
|
Weight |
400
g
|
The
iX 132, Audio Input Card is the system line-level preamplifier card.
This card is to be installed in the iX 101 or iX 102 Matrix Main Frame
only. Each card has a DIP switch on board for card address setting.
This card accommodates 4 line-level audio input channels. Each audio
input channel accepts a balanced audio input and a opto-coupler audio
control input activation. Each audio input channel comes with individual
input gain control and signal indication LED.
|
|
iX
132
|
|
Number
of Audio-Input Channel
|
4
nos.
|
|
Audio
Input Sensitivity & Impedance
|
0
dBV, 10 kΩ, Balanced |
|
Digital
Audio |
16
bit ADC
|
|
Sampling
Rate |
48
kHz
|
| |
Number
of Audio Control Input
|
4
nos. of Opto-Coupler Activation |
| |
Connection
|
4
nos. 5-pin Panel Feed Through Connector |
| |
Indicator
|
4
nos. Peak LED |
| |
Control
|
4
nos. Gain Conrol |
| |
Material
& Finish
|
Mild
Steel; Epoxy Coated Steele Blue (RAL 5011)
|
| |
Dimensions
(W x H x D)
|
26
x 220 x 286 mm |
| |
Weight |
348
g |
The
iX 133, Remote Microphone Input Card is the system remote microphone
preamplifier card. This card is to be installed in the iX 101 or iX
102 Matrix Main Frame only. Each card has a DIP switch on board for
card address setting. This card accomodates 4 numbers of iX 151, Matrix
Remote Microphone input channels. Each remote microphone input channel
accepts a balanced microphone input and a communication data input.
Each channel comes with a signal indication LED. These communication-input
channels accept communication data from iX 153, Remote Control Sensor
Panel and iX 154, Remote Multipurpose Relay Panel as well.
|
|
iX
133
|
|
Number
of Remote Microphone Input Channel
|
4
nos.
|
|
Remote
Microphone Input Sensitivity & Impedance
|
+6
dBV, 10 kΩ, Balanced |
|
Digital
Audio
|
16
bit ADC
|
|
Sampling
Rate
|
48
kHz
|
| |
Number
of Data Communoication Channel
|
4
nos. |
| |
Data
Communication Protocol
|
RS-485 |
| |
Connection
|
4
nos. 5-Pin Panel Feed Through Connector |
| |
Indicator
|
4
nos. Peak LED |
| |
Material
& Finish
|
Mild
Steel; Epoxy Coated Steele Blue (RAL 5011)
|
| |
Dimensions
(W x H x D)
|
26
x 220 x 286 mm |
| |
Weight |
346
g |
The
iX 136, Audio Output Card is the system line amplifier card. This
card can be installed in any matrix frames. Each card has a DIP switch
on board for card address setting. This card provides 4 line-level
audio output channels to be fed into the power amplifier. Each audio
output channel is equipped with an opto-coupler audio control output
for external triggering. Each audio output channels volume control
is software-driven. Each audio output channel is protected against
any digital failure with automatic analog microphone overriding.
|
|
iX
136
|
|
Number
of Audio Output Channel
|
4
nos.
|
|
Audio
Output Level & Impedance
|
0
dBV, 600 Ω, Balanced |
|
Digital
Audio
|
16
bit ADC
|
|
Sampling
Rate
|
48
kHz
|
| |
Numbering
of Audio Control Output
|
4
nos. of Opto-coupler Activation |
| |
Connection
|
4
nos. 5-Pin Panel Feed Through Connector |
| |
Material
& Finish
|
Mild
Steel; Epoxy Coated Steele Blue (RAL 5011)
|
| |
Dimensions
(W x H x D)
|
26
x 220 x 286 mm |
| |
Weight |
430
g |
The
iX 142, Control Sensor Card is the system control input card. This
card can be installed in any matrix frames. Each card has a DIP switch
on board for card address setting. This card provides 16 control input
channels. Each control input channel can be set to accept a dry-contact
or current loop sensing. Individual control-input channel can be set
to interlock with control-input channel 8 or 16 for controlled and
synchronised triggering.
|
|
iX
142
|
|
Number
of Contol-Input Channel
|
16
nos.
|
|
Sensing
Method
|
Dry
Contact or Current Loop (jumper selectable) |
|
Dry
Contact Method
|
NO
or NC (jumper selectable)
|
|
Current
Loop Method
|
Released
Voltage 24 Vdc, 5 mA
|
| |
Connection
|
2
nos. 16-Pin Panel Feed Through Connector |
| |
Material
& Finish
|
Mild
Steel; Epoxy Coated Steele Blue (RAL 5011)
|
| |
Dimensions
(W x H)
|
26
x 220 x 286 mm |
| |
Weight
|
324
g |
The
iX 143, Multipurpose Relay Card is the system control output card.
This card can be installed in any matrix frames. Each card has a DIP
switch on board for card address setting. This card provides 16 control-
output channels. Each control-output channel can be set to be a normally
open (NO) or normally close (NC) dry-contact activation.
|
|
iX
143
|
|
Number
of Contol-Input Channel
|
16
nos.
|
|
Trigger
Method
|
NO
or NC Dry-contact (jumper selectable) |
|
Withstand
Voltage |
30
Vdc, 250 mA
|
|
Connection
|
2
nos. 16-Pin Panel Feed Through Connector
|
| |
Material
& Finish
|
Mild
Steel; Epoxy Coated Steele Blue (RAL 5011) |
| |
Dimensions
(W x H x D)
|
26
x 220 x 286 mm |
| |
Weight |
330
g |
The
iX 151, Matrix Remote Microphone can be placed up to 1.2 km away from
the Main Frame. This remote mircophone is to be connected to iX 133,
Remote Microphone Input Card. The remote microphone operates in 2
modes: Individual Zone Paging Mode and Group Paging Mode. In the Individual
Zone Paging Mode, the zone selection can be done through the numerical
entry on its keys. In the Group Paging Mode, the group of zones can
be configured through iX 100 Series, proprietary Control Manager and
activate through the remote microphones keys assigned. The remote
microphone can be configured to have different types of chime to precede
any paging. The remote microphone is equipped with two general purpose
function keys. These function keys can be assigned to activate a relay
on the iX 143, Multipurpose Relay Card or to sound a built-in siren.
|
|
iX
151
|
|
Microphone |
Non-removable
condenser gooseneck microphone
|
|
Audio
Output Level & Impedance
|
+6
dBV, 600 Ω, Balanced |
|
Frequency
Response |
200
Hz to 12.5 kHz
|
|
Signal-to-Noise
Ratio |
>
60 dB (@ 0 dBV)
|
| |
THD
+ N |
<
0.15% (@ 1 kHz)
|
| |
Paging
Mode |
Individual
Mode (Up to output zone-384, 30 zones at a time)
Group Mode (Up to 20 groups)
|
| |
Indicator |
16
x 2 character LCD
10 Individual Group LEDs
Function Key (F1 & F2), Paging Mode, Group A/B, Enter, Clear,
TALK, Operation fault, TX and RX
|
| |
Control |
Chime
level control (2-tone, 4-tone, gong & siren)
Audio level control
20 kHz Pilot Tone level control
LCD Contrast Control
|
| |
Switches |
10
Individual Group Switches
Function Key (F1 & F2), Paging Mode, Group A/B, Enter, Clear,
TALK, Reset button
|
| |
Connection |
Power:
+24 Vdc & Ground
Audio: Hot & Cold
Data: COM+ & COM-
|
| |
Distance
from Main Frame
|
Up
to 1.2 km
|
| |
Power
Requirement
|
+24
Vdc, 140 mA
|
| |
Material
& Finish |
ABS
Resin, Aluminium & Mild Steel;
Epoxy Coated Steele Blue (RAL 5011)
|
| |
Dimensions
(W x H x D) |
195
x 65 x 190 mm
|
| |
Weight |
1.0
kg |
The
iX 153, Remote Control Sensor Panel is the remote version of the iX
142, Control Sensor Card. This control-input panel can be placed up
to 1.2 km away from the main frame. Its communication data signal
is to be connected to the iX 133, Remote Microphone Input Card. This
panel houses 16 control input channels. Each control-input channel
can be set to accept dry contact or current loops sensing.
|
|
iX
153
|
|
Number
of Control-
Input Channel
|
16
nos.
|
|
Sensing
Method
|
Dry
Contact or Current Loop (jumper selectable)
|
|
Dry
Contact Method
|
NO
or NC (jumper selectable)
|
|
Current
Loop Method
|
Released
Voltage 24 Vdc, 5 mA
|
| |
Connection
|
9
nos. 4-Pin Panel Feed Through Connector
|
| |
Indicator |
1
Power LED
1 Rx LED
1 Tx LED
|
| |
Distance
from Main Frame
|
Up
to 1.2 km |
| |
Power
Requirement
|
110
Vac / 220 Vac; 50 / 60 Hz selectable |
| |
Material
& Finish
|
Mild
Steel; Epoxy Coated Steele Blue (RAL 5011)
|
| |
Dimensions
(W x H x D)
|
483
x 44 200 mm |
| |
Weight |
2.4
kg |
The
iX 154, Remote Multipurpose Relay Panel is the remote version of the
iX 143, Multipurpose Relay Card. This control-output panel can be
placed up to 1.2 km away from the main frame. Its communication data
signal is to be connected to the iX 133, Remote Microphone Input Card.
This panel houses 16 control-output channels. Each control-output
channel can be set to be a NO or NC dry-contact activation.
|
|
iX
154
|
|
Number
of Control-
Output Channel
|
16
nos.
|
|
Triggering
Method
|
NO
or NC Dry-contact (jumper selectable)
|
|
Withstand
Voltage |
30
Vdc, 250 mA
|
|
Connection
|
9
nos. 4-Pin Panel Feed Through Connector
|
| |
Indicator |
1
Power LED
1 Rx LED
1 Tx LED
|
| |
Distance
from Main Frame
|
Up
to 1.2 km |
| |
Power
Requirement
|
110
Vac / 220 Vac; 50 / 60 Hz selectable |
| |
Material
& Finish
|
Mild
Steel; Epoxy Coated Steele Blue (RAL 5011)
|
| |
Dimensions
(W x H x D)
|
483
x 44 x 200 mm |
| |
Weight
|
2.4
kg |
The
iX 155, Internet Connectivity Panel is the system gateway to the Local
Area Network (LAN) and Wide Area Network (WAN). This panel is able
to monitor the status and upload the configuration to the matrix system
from a remote client. This panel is to be connected to the RS-232
port of the iX 121, Central Processing Card I on one end and to a
modem or the ethernet on the other end. For modem dial-up, the panel
can be activated remotely through a PPP dial-up. For ethernet connection,
it is to be connected to the LAN. This panel is able to send email
to 5 designated addresses upon any fault detected.
|
|
iX
155
|
|
Modem
Dial-up |
56
kbps
|
|
Remote
Access
Service
|
PPP
(Client and Server) |
|
Network
Interface |
10-Base
T
|
|
Network
Protocol
|
TCP/IP,
UDP, FTP SMTP, ICMP, ARP
|
| |
Number
of Control-Output Channel
|
2
nos.
|
| |
Triggering
Method
|
NO
or NC Dry-contact (jumper selectable) |
| |
Withstand
Voltage
|
30
Vdc, 250 mA |
| |
Connection |
-
1 no. 2-way terminal Block
- 1 no. 4-Pin Panel Feed Through Connector
- 2 nos. 9-Pin D-sub (Male) Connector
- 1 no. RJ-45 Socket
|
| |
Indicator |
1
Power LED
1 Rx LED
1 Tx LED
1 Ethernet Link
Control Output 1 & 2 Status
|
| |
Switches
|
Control
Output 1 & 2 Reset Switches |
| |
Power
Requirement
|
110
Vac / 220 Vac; 50 / 60 Hz selectable |
| |
Material
& Finish
|
Mild
Steel: Epoxy Coated Steele Blue (RAL 5011)
|
| |
Dimensions
(W x H x D)
|
483
x 44 x 200 mm |
| |
Weight
|
2.2
kg |
|
|