iX Series PDF

 

The iX 101 & iX 102, Single and Dual CPC Main Frame are rack-mountable frames and used to house the Digital Matrix System modular cards. Both can accommodate up to 12 matrix cards. All the Digital Matrix audio and remote microphone input cards shall be placed within this frame. This main frame comes complete with a front access LCD panel with selection scroll keys; 1 unit of iX 182 Power Supply Unit; 1 unit of iX 194 Analogue Handheld Microphone; 1 unit of iX 121 Central Processing Card I for iX 101 (2 units of iX 121 Central Processing Card I for iX 102); 1 unit of iX 132 Audio Input Card; 1 unit of iX 133 Remote Microphone Input Card and 2 units of iX 136 Audio Output Cards.

iX 101 / 102

Input Capacity 12 Cards

Available Card Slots 7 Slots (iX 101)
6 Slots (iX 102)

Microphone iX 194 Analogue Handheld Microphone

Indicator (Facial) 240 x 128 Dot Matrix LCD

Control (Facial) 4 nos. Scroll keys
2 nos. Function keys
1 no. LCD Contrast control
1 no. Gain adjust for iX 194 Analogue
Handheld Microphone

  Number of Audio Input Channel

4 nos.
  Audio Input Sensitivity & Impedance

0 dBV, 10 kΩ, Balanced
  Number of Audio Control Input

4 nos. Dry-contact Activation
  Number of Remote Microphone Input Channel

4 nos.
  Remote Microphone Input Sensitivity & Impedance

+ 6 dBV, 10 kΩ, Balanced
  Number of Data Communication Channel

4 nos.

  Data Communication Protocol

RS-485
  Number of Audio Output Channel

8 nos.

  Audio Output Level & Impedance

0 dBV, 600 Ω, Balanced

  Number of Audio Control Output

8 nos. Opto-coupler Activation

  Frequency Response 20 Hz to 20 kHz (-3 dB)

  Signal-to-Noise Ratio > 80 dB (@ 0 dBV)

  THD + N < 0.03% (@ 1 kHz)

  Power Requirement 240 Vac, 50 Hz
DC Backup: 24 Vdc, 6.5 A

  Material & Finish Mild Steel; Epoxy Coated
Steele Blue (RAL 5011)

  Dimensions (W x H x D) 483 x 221 x 360 mm

  Weight 12.2 kg (iX 101)
12.6 kg (iX 102)



The iX 103, Extension Frame is a rack-mountable frame and is used to house the Digital Matrix System modular cards. It can accomodate up to 12 matrix cards. This extension frame comes complete with 1 unit of iX 182 Power Supply Unit; 1 unit of iX 122 Central Processing Card II; 1 unit of iX 123 Extension Card; 1 unit of iX 191 Network Bus and 1 unit of iX 192 Audio Bus.

iX 103

Input Capacity 12 Cards

Available Card Slots 10 Slots

Power Requirement 240 Vac, 50 Hz
DC Backup: 24 Vdc, 6.5 A


Material & Finish Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

Dimensions (W x H x D)

483 x 221 x 360 mm
  Weight 10 kg


The iX 121, Central Processing Card I is the main controller that manage the entire matrix system operation. It is to be installed in the iX 101 or iX 102 Matrix Main Frame. It occupies Slot-1 of iX 101 Main Frame or Slot-1 and Slot-2 of iX 102 Main Frame. This card will be connected to PC via the RS-232 Serial Communication Port for system configuration upload and system status download. This RS-232 port is also used to connect to iX 155 Internet Connectivity Panel, via a selector slide switch on the panel facial. Two units of iX 121 will be installed into the iX 102, Dual CPC Matrix Main Frame.

iX 121

Connection 2 nos. 9-pin D-sub (Female) Connector - CAN
1 no. 9-pin D-sub (Male) Connector - RS-232

Indicator 1 no. Power LED
1 no. Faulty LED
1 no. Operation LED

Control 1 slide switch

Backup Power Internal Battery, 3V Lithium

Material & Finish


Mild Steel; Epoxy Coated Steele Blue (RAL 5011)
  Dimensions (W x H x D)

26 x 220 x 286 mm
  Weight

354 g


The iX 122, Central Processing Card II is installed in the iX 103, Matrix Extension Frame. It occupies Slot-1 of the Extension Frame. The central processing cards between frames are connected through Controller Area Network (CAN) Protocol.

iX 122

Connection 2 nos. 9-Pin D-sub (Female) Connector -CAN

Indicator 1 no. Power LED
1 no. Faulty LED
1 no. Operation LED


Material & Finish Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

Dimensions ( W x H x D) 26 x 220 x 286 mm

Weight 321 g


The iX 123, Extension Card transfers the digital audio signals, control and communication signals from one frame to another. It shall be placed next to the iX 121 or iX 122.

iX 123

Connection 1 nos. 50-Pin Centronic (Female) Connector

Material & Finish Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

Dimensions (W x H x D) 26 x 220 x 286 mm

Weight 400 g



The iX 132, Audio Input Card is the system line-level preamplifier card. This card is to be installed in the iX 101 or iX 102 Matrix Main Frame only. Each card has a DIP switch on board for card address setting. This card accommodates 4 line-level audio input channels. Each audio input channel accepts a balanced audio input and a opto-coupler audio control input activation. Each audio input channel comes with individual input gain control and signal indication LED.

iX 132

Number of Audio-Input Channel

4 nos.

Audio Input Sensitivity & Impedance

0 dBV, 10 kΩ, Balanced
Digital Audio 16 bit ADC

Sampling Rate 48 kHz

  Number of Audio Control Input

4 nos. of Opto-Coupler Activation
  Connection

4 nos. 5-pin Panel Feed Through Connector
  Indicator

4 nos. Peak LED
  Control

4 nos. Gain Conrol
  Material & Finish

Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

  Dimensions (W x H x D)

26 x 220 x 286 mm
  Weight 348 g


The iX 133, Remote Microphone Input Card is the system remote microphone preamplifier card. This card is to be installed in the iX 101 or iX 102 Matrix Main Frame only. Each card has a DIP switch on board for card address setting. This card accomodates 4 numbers of iX 151, Matrix Remote Microphone input channels. Each remote microphone input channel accepts a balanced microphone input and a communication data input. Each channel comes with a signal indication LED. These communication-input channels accept communication data from iX 153, Remote Control Sensor Panel and iX 154, Remote Multipurpose Relay Panel as well.

iX 133

Number of Remote Microphone Input Channel

4 nos.

Remote Microphone Input Sensitivity & Impedance

+6 dBV, 10 kΩ, Balanced
Digital Audio

16 bit ADC

Sampling Rate

48 kHz

  Number of Data Communoication Channel

4 nos.
  Data Communication Protocol

RS-485
  Connection

4 nos. 5-Pin Panel Feed Through Connector
  Indicator

4 nos. Peak LED
  Material & Finish

Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

  Dimensions (W x H x D)

26 x 220 x 286 mm
  Weight 346 g


The iX 136, Audio Output Card is the system line amplifier card. This card can be installed in any matrix frames. Each card has a DIP switch on board for card address setting. This card provides 4 line-level audio output channels to be fed into the power amplifier. Each audio output channel is equipped with an opto-coupler audio control output for external triggering. Each audio output channel’s volume control is software-driven. Each audio output channel is protected against any digital failure with automatic analog microphone overriding.

iX 136

Number of Audio Output Channel

4 nos.

Audio Output Level & Impedance

0 dBV, 600 Ω, Balanced
Digital Audio

16 bit ADC

Sampling Rate

48 kHz

  Numbering of Audio Control Output

4 nos. of Opto-coupler Activation
  Connection

4 nos. 5-Pin Panel Feed Through Connector
  Material & Finish

Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

  Dimensions (W x H x D)

26 x 220 x 286 mm
  Weight 430 g


The iX 142, Control Sensor Card is the system control input card. This card can be installed in any matrix frames. Each card has a DIP switch on board for card address setting. This card provides 16 control input channels. Each control input channel can be set to accept a dry-contact or current loop sensing. Individual control-input channel can be set to interlock with control-input channel 8 or 16 for controlled and synchronised triggering.

iX 142

Number of Contol-Input Channel

16 nos.

Sensing Method

Dry Contact or Current Loop (jumper selectable)
Dry Contact Method

NO or NC (jumper selectable)

Current Loop Method

Released Voltage 24 Vdc, 5 mA

  Connection

2 nos. 16-Pin Panel Feed Through Connector
  Material & Finish

Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

  Dimensions (W x H)

26 x 220 x 286 mm
  Weight

324 g


The iX 143, Multipurpose Relay Card is the system control output card. This card can be installed in any matrix frames. Each card has a DIP switch on board for card address setting. This card provides 16 control- output channels. Each control-output channel can be set to be a normally open (NO) or normally close (NC) dry-contact activation.

iX 143

Number of Contol-Input Channel

16 nos.

Trigger Method

NO or NC Dry-contact (jumper selectable)
Withstand Voltage 30 Vdc, 250 mA

Connection

2 nos. 16-Pin Panel Feed Through Connector

  Material & Finish


Mild Steel; Epoxy Coated Steele Blue (RAL 5011)
  Dimensions (W x H x D)

26 x 220 x 286 mm
  Weight 330 g


The iX 151, Matrix Remote Microphone can be placed up to 1.2 km away from the Main Frame. This remote mircophone is to be connected to iX 133, Remote Microphone Input Card. The remote microphone operates in 2 modes: Individual Zone Paging Mode and Group Paging Mode. In the Individual Zone Paging Mode, the zone selection can be done through the numerical entry on its keys. In the Group Paging Mode, the group of zones can be configured through iX 100 Series, proprietary Control Manager and activate through the remote microphone’s keys assigned. The remote microphone can be configured to have different types of chime to precede any paging. The remote microphone is equipped with two general purpose function keys. These function keys can be assigned to activate a relay on the iX 143, Multipurpose Relay Card or to sound a built-in siren.

iX 151

Microphone Non-removable condenser gooseneck microphone

Audio Output Level & Impedance

+6 dBV, 600 Ω, Balanced
Frequency Response 200 Hz to 12.5 kHz

Signal-to-Noise Ratio > 60 dB (@ 0 dBV)

  THD + N < 0.15% (@ 1 kHz)

  Paging Mode Individual Mode (Up to output zone-384, 30 zones at a time)
Group Mode (Up to 20 groups)

  Indicator 16 x 2 character LCD
10 Individual Group LEDs
Function Key (F1 & F2), Paging Mode, Group A/B, Enter, Clear, TALK, Operation fault, TX and RX

  Control Chime level control (2-tone, 4-tone, gong & siren)
Audio level control
20 kHz Pilot Tone level control
LCD Contrast Control

  Switches 10 Individual Group Switches
Function Key (F1 & F2), Paging Mode, Group A/B, Enter, Clear, TALK, Reset button

  Connection Power: +24 Vdc & Ground
Audio: Hot & Cold
Data: COM+ & COM-

  Distance from Main Frame

Up to 1.2 km
  Power Requirement

+24 Vdc, 140 mA
  Material & Finish ABS Resin, Aluminium & Mild Steel;
Epoxy Coated Steele Blue (RAL 5011)

  Dimensions (W x H x D) 195 x 65 x 190 mm

  Weight 1.0 kg


The iX 153, Remote Control Sensor Panel is the remote version of the iX 142, Control Sensor Card. This control-input panel can be placed up to 1.2 km away from the main frame. Its communication data signal is to be connected to the iX 133, Remote Microphone Input Card. This panel houses 16 control input channels. Each control-input channel can be set to accept dry contact or current loops sensing.

iX 153

Number of Control-
Input Channel

16 nos.

Sensing Method


Dry Contact or Current Loop (jumper selectable)
Dry Contact Method

NO or NC (jumper selectable)

Current Loop Method

Released Voltage 24 Vdc, 5 mA
  Connection

9 nos. 4-Pin Panel Feed Through Connector
  Indicator 1 Power LED
1 Rx LED
1 Tx LED

  Distance from Main Frame

Up to 1.2 km
  Power Requirement

110 Vac / 220 Vac; 50 / 60 Hz selectable
  Material & Finish

Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

  Dimensions
(W x H x D)

483 x 44 200 mm
  Weight 2.4 kg


The iX 154, Remote Multipurpose Relay Panel is the remote version of the iX 143, Multipurpose Relay Card. This control-output panel can be placed up to 1.2 km away from the main frame. Its communication data signal is to be connected to the iX 133, Remote Microphone Input Card. This panel houses 16 control-output channels. Each control-output channel can be set to be a NO or NC dry-contact activation.

iX 154

Number of Control-
Output Channel

16 nos.

Triggering Method

NO or NC Dry-contact (jumper selectable)
Withstand Voltage 30 Vdc, 250 mA

Connection

9 nos. 4-Pin Panel Feed Through Connector
  Indicator 1 Power LED
1 Rx LED
1 Tx LED

  Distance from Main Frame

Up to 1.2 km
  Power Requirement

110 Vac / 220 Vac; 50 / 60 Hz selectable
  Material & Finish

Mild Steel; Epoxy Coated Steele Blue (RAL 5011)

  Dimensions
(W x H x D)

483 x 44 x 200 mm
  Weight

2.4 kg


The iX 155, Internet Connectivity Panel is the system gateway to the Local Area Network (LAN) and Wide Area Network (WAN). This panel is able to monitor the status and upload the configuration to the matrix system from a remote client. This panel is to be connected to the RS-232 port of the iX 121, Central Processing Card I on one end and to a modem or the ethernet on the other end. For modem dial-up, the panel can be activated remotely through a PPP dial-up. For ethernet connection, it is to be connected to the LAN. This panel is able to send email to 5 designated addresses upon any fault detected.

iX 155

Modem Dial-up 56 kbps

Remote Access
Service

PPP (Client and Server)
Network Interface 10-Base T

Network Protocol

TCP/IP, UDP, FTP SMTP, ICMP, ARP
  Number of Control-Output Channel

2 nos.
  Triggering Method

NO or NC Dry-contact (jumper selectable)
  Withstand Voltage

30 Vdc, 250 mA
  Connection - 1 no. 2-way terminal Block
- 1 no. 4-Pin Panel Feed Through Connector
- 2 nos. 9-Pin D-sub (Male) Connector
- 1 no. RJ-45 Socket

  Indicator 1 Power LED
1 Rx LED
1 Tx LED
1 Ethernet Link
Control Output 1 & 2 Status

  Switches

Control Output 1 & 2 Reset Switches
  Power Requirement

110 Vac / 220 Vac; 50 / 60 Hz selectable
  Material & Finish

Mild Steel: Epoxy Coated Steele Blue (RAL 5011)

  Dimensions (W x H x D)

483 x 44 x 200 mm
  Weight

2.2 kg
 

Site Map | Privacy Policy | Terms of Use